HITACHI
Hitachi Science Instruments is a wholly-owned subsidiary established in Beijing by Hitachi Hi-Tech Co., Ltd., a subsidiary of Hitachi Group. The main products include various liquid chromatography, fluorescence spectrophotometers, ultraviolet spectrophotometers, atomic absorption spectrophotometers, electrochemistry and other analytical instruments.
model | Baseline stability |
| 0.0004Abs/30min |
model | Maximum pressure resistance | Flow accuracy | Injection range | Wavelength range |
60MPa | ≤0.05% | 0.1-100uL | 190-900nm | |
| Primaide PLUS | 39.2 MPa | ≤0.075% | 0.1-50uL | 190-900nm |
| ChromasterUltra Rs | 140MPa | 0.06%RSD | 0.1-20ul | 100-900nm |
| LA8080 | ||||
| UHPLC Chromatography column LaChromUltraII C18 | ||||
| ChromAssist4.1 Database chromatography data management system |
model | Dispersion unit | Slit nm |
Grating | 1~20 | |
| F-2710 | Grating | 2.5~20 |
| EEM® View | Grating | 1~20 |
| F-7000 | Grating | 1~20 |
| F-7100 | Grating | 1~20 |
Accessories | Corresponding model | Accessories description |
| F-7100 | Optimize the testing of solid, powder or high concentration solution samples.Avoid specular reflected light reflected from the sample surface into the emitter monochromator. | |
| Absorption spectroscopy stent 650-0165 | F-7100 | Compatible with sample pool, 10 mm Square sample pool.Absorption spectroscopy can be performed.By inspiring /Synchronous spectrum of emission wavelength can obtain an absorption spectrum that is not affected by fluorescence. |
| High sensitivity sample pool holder 5 J0-0124 | F-7100 | Compatible with sample pool, 10 mm Square sample pool.Use 10 mm A conventional sample cell can achieve double sensitivity.With 10 mm Conventional sample pool (This attachment does not include )compatible. |
| Micropool bracket 4 J1-0133 | F-7100 | Combined with commercial micro sample pools, the micro liquid sample testing is realized. |
| Automatic filter accessories 5 J0-0158 | F-7100 | Automatically embed appropriate filters according to the test conditions, and no higher-order light can be obtained (1/2,1/3,2,3...Step light )the spectrum of influence. |
| Filter Kit 5 J0-0151 | F-7100 | The cutoff filter can help eliminate false signals caused by level 2 light.In addition, the filter can be used to eliminate interference signals on the excitation side or the emission side. |
| Gloss reduction plate kit 251-0081 | F-7100 | Used to analyze highly fluorescent materials that cannot be diluted or to reduce the energy or fluorescence intensity of the light source. |
| Sample Suction Device 5 J0-0123 | F-7100 | Online continuous sampling, measurement and result output, especially suitable for the fields of quality control and clinical chemical analysis, automatic and continuous liquid sample measurement. |
| 8Pool conversion sample rack 250-0333 | F-7100 | Suitable for measurement of multiple samples, can place 8 10 mm for rapid quantitative analysis of standard cuvettes or test tubes. |
| 4Pool conversion sample rack 250-0339 | F-7100 | Use 10 mm Standard sample cells are subjected to rapid quantitative analysis. |
| Automatic 4-cell conversion constant temperature sample pool 5 J0-0140 | F-7100 | 410 mm Regular sample pool, automatic switching for rapid quantitative testing (No circulation constant temperature sink or sample pool ) |
model | Features and parameters |
| Automatic wavelength, dual beam, wavelength: 190 ~1100nm, Accuracy ±0.3nm, Bandwidth 1 nm | |
| UH5210 | Automatic wavelength, dual beam, wavelength: 190 ~1100nm, Accuracy ±0.3nm, Bandwidth 1.5 nm |
| U-3900/U-3900H | Dual beam, automatic wavelength, ultraviolet visible near infrared: 190-2600 nm, Spectral bandwidth: 0.1 /0.5/1/2/4/5nm, Wavelength accuracy: ±0.1nm |
| UH5700 | Automatic wavelength, dual beam, wavelength: 190 ~3300nm, bandwidth UV-Vis:0.1、0.2、0.5、1、2、5、10nm;NIR:0.25、0.5nm,Automatic control(1 to 35nm) |
| U-2900/2910 | Automatic wavelength, dual beam, wavelength: 190 ~1100nm, Accuracy ±0.3nm, Bandwidth 1.5 nm |
| UH4150 | Automatic wavelength, dual beam, wavelength: 190 ~2600nm, Spectral bandwidth: UV visible: automatic regulation, maximum 14.4 nm, 0.01 can be entered manually ~8nm Near infrared: automatic regulation, maximum 36 nm, 0.1 can be entered manually ~20nm |
| UH4150AD+ | Automatic wavelength, dual beam, wavelength: 175 ~2000nm, Accuracy UV-visible light zone: ±0.2nm, Near infrared zone: ±1.0nm |
Accessories | Corresponding model | Accessories description |
| U-5100 | The automatic sample suction device can aspirate samples from the test tube and automatically measure them. | |
| Single colorimetric pool bracket (P/N 3J2-0110) | U-5100 | Use this bracket to use a 10 mm The square colorimetric pool of optical path is measured.Accommodate a colorimetric pool. |
| Right angle long-path colorimetric pool bracket (P/N 3J2-0111) | U-5100 | Use this bracket to hold 10, 20, 30, 40, 50 or 100 mm Colorimetric pool of optical path.Accommodate a colorimetric pool at a time. The use of long-path colorimetric cells can improve the measurement sensitivity of low-concentration samples. |
| Micropool mask (P/N 200-1537) | U-5100 | When measuring micro samples, use transparent microcells instead of black edge walls, and this component is required. |