Product/Brand

HITACHI

Hitachi Science Instruments is a wholly-owned subsidiary established in Beijing by Hitachi Hi-Tech Co., Ltd., a subsidiary of Hitachi Group. The main products include various liquid chromatography, fluorescence spectrophotometers, ultraviolet spectrophotometers, atomic absorption spectrophotometers, electrochemistry and other analytical instruments.

Click to expand
Tititrator

model

Measurement range

COM-A19

-2000~2000mV
MOICO-A19

MOIVO-A19
COM-28/28S

AQ-300

AQV-300
Atomic absorption

model

Baseline stability

ZA4000

0.0004Abs/30min
Liquid chromatography-amino acid analysis

model

Maximum pressure resistance

Flow accuracy

Injection rangeWavelength range

Chromaster plus

60MPa

≤0.05%

0.1-100uL190-900nm
Primaide PLUS

39.2 MPa

≤0.075%

0.1-50uL190-900nm
ChromasterUltra Rs140MPa0.06%RSD0.1-20ul100-900nm
LA8080



UHPLC Chromatography column LaChromUltraII C18



ChromAssist4.1 Database chromatography data management system





Fluorescence spectrophotometer

model

Dispersion unit

Slit nm

F-4700

Grating

1~20
F-2710

Grating

2.5~20
 EEM® View
Grating1~20
 F-7000Grating1~20
F-7100Grating1~20

Accessories

Corresponding modelAccessories description

Solid Sample Stent 5 J0-0152

F-7100Optimize the testing of solid, powder or high concentration solution samples.Avoid specular reflected light reflected from the sample surface into the emitter monochromator.
Absorption spectroscopy stent 650-0165F-7100Compatible with sample pool, 10 mm Square sample pool.Absorption spectroscopy can be performed.By inspiring /Synchronous spectrum of emission wavelength can obtain an absorption spectrum that is not affected by fluorescence.
High sensitivity sample pool holder 5 J0-0124
F-7100Compatible with sample pool, 10 mm Square sample pool.Use 10 mm A conventional sample cell can achieve double sensitivity.With 10 mm Conventional sample pool (This attachment does not include )compatible.
Micropool bracket 4 J1-0133F-7100Combined with commercial micro sample pools, the micro liquid sample testing is realized.
Automatic filter accessories 5 J0-0158F-7100Automatically embed appropriate filters according to the test conditions, and no higher-order light can be obtained (1/2,1/3,2,3...Step light )the spectrum of influence.
Filter Kit 5 J0-0151F-7100The cutoff filter can help eliminate false signals caused by level 2 light.In addition, the filter can be used to eliminate interference signals on the excitation side or the emission side.
Gloss reduction plate kit 251-0081
F-7100Used to analyze highly fluorescent materials that cannot be diluted or to reduce the energy or fluorescence intensity of the light source.
Sample Suction Device 5 J0-0123F-7100Online continuous sampling, measurement and result output, especially suitable for the fields of quality control and clinical chemical analysis, automatic and continuous liquid sample measurement.
8Pool conversion sample rack 250-0333F-7100Suitable for measurement of multiple samples, can place 8 10 mm for rapid quantitative analysis of standard cuvettes or test tubes.
4Pool conversion sample rack 250-0339F-7100Use 10 mm Standard sample cells are subjected to rapid quantitative analysis.
Automatic 4-cell conversion constant temperature sample pool 5 J0-0140F-7100410 mm Regular sample pool, automatic switching for rapid quantitative testing (No circulation constant temperature sink or sample pool )


UV-visible spectrophotometer


model

Features and parameters

UH5300

Automatic wavelength, dual beam, wavelength: 190 ~1100nm, Accuracy ±0.3nm, Bandwidth 1 nm
UH5210Automatic wavelength, dual beam, wavelength: 190 ~1100nm, Accuracy ±0.3nm, Bandwidth 1.5 nm
U-3900/U-3900HDual beam, automatic wavelength, ultraviolet visible near infrared: 190-2600 nm, Spectral bandwidth: 0.1 /0.5/1/2/4/5nm, Wavelength accuracy: ±0.1nm
UH5700Automatic wavelength, dual beam, wavelength: 190 ~3300nm, bandwidth UV-Vis:0.1、0.2、0.5、1、2、5、10nm;NIR:0.25、0.5nm,Automatic control(1 to 35nm)
U-2900/2910Automatic wavelength, dual beam, wavelength: 190 ~1100nm, Accuracy ±0.3nm, Bandwidth 1.5 nm
UH4150Automatic wavelength, dual beam, wavelength: 190 ~2600nm, Spectral bandwidth: UV visible: automatic regulation, maximum 14.4 nm, 0.01 can be entered manually ~8nm Near infrared: automatic regulation, maximum 36 nm, 0.1 can be entered manually ~20nm
UH4150AD+

Automatic wavelength, dual beam, wavelength: 175 ~2000nm, Accuracy UV-visible light zone: ±0.2nm, Near infrared zone: ±1.0nm


Accessories

Corresponding modelAccessories description

Automatic sample suction device (P/N 3J2-0105)

U-5100The automatic sample suction device can aspirate samples from the test tube and automatically measure them.
Single colorimetric pool bracket (P/N 3J2-0110)U-5100Use this bracket to use a 10 mm The square colorimetric pool of optical path is measured.Accommodate a colorimetric pool.
Right angle long-path colorimetric pool bracket (P/N 3J2-0111)U-5100Use this bracket to hold 10, 20, 30, 40, 50 or 100 mm Colorimetric pool of optical path.Accommodate a colorimetric pool at a time.
The use of long-path colorimetric cells can improve the measurement sensitivity of low-concentration samples.
Micropool mask (P/N 200-1537)U-5100When measuring micro samples, use transparent microcells instead of black edge walls, and this component is required.