ZA4000 Series atomic absorption spectrophotometers, new fast continuous mode (supports flame method), achieving higher analysis efficiency, can beWe have achieved rapid, high precision and high reproducibility in many fields such as research and quality management.
Features
High-precision and efficient detection through rapid continuous measurement
Continuous measurement of up to 12 elements can be carried out to achieve high efficiency detection
ZA4000 The series is equipped with the polarization Zeeman calibration method specially developed by Hitachi and dual detectors to provide stable and high-precision analysis.
Among the new members, the fast serial flame machine ZA4800 Using the newly developed diffraction grating drive, the multi-element rapid continuous testing is achieved, and the detection efficiency is improved by 30%, breaking the AAS Determination speed is not as good as ICP technical difficulties.

High-precision background correction for full wavelength range, suitable for any element, can correct sodium and potassium, etc. D2 Elements that cannot be corrected by the lamp correction method.

It can be tested by turning on the computer, and the baseline is more stable.

Using a separate detector to simultaneously capture the signal of the sample beam and the reference beam, which can reduce baseline noise.
The detection time of the two beams is synchronized, thereby improving the correction accuracy.

The polarization Zeeman correction method can effectively suppress drift, and the absorbance will return to about zero when the blank solution is inhaled. Therefore, the system will determine the start and end time of injection and measurement, and automatically perform the measurement. Notify when the sample needs to be replaced via voice prompt. Even customers who use atomic absorption spectrophotometers for the first time can operate with confidence.

When ultra-trace analysis is performed using graphite furnace method, contamination of the graphite tube or sample injection system will lead to inaccurate analysis data. Through the "Graphite Tube Pollution Confirmation" function, beginners can also easily analyze and promptly detect instrument pollution, saving pre-inspection time.

It can improve the accuracy of the detection results. Automatically detects the blast boiling and will be marked after the value of the measurement result“ P”。 Based on this, it can be confirmed whether the boiling occurs and the heating procedure can be corrected in time.

According to the set automatic sampler conditions, the display screen of the sample disk will display standard solutions, matrix modifiers, etc. in different colors according to the sample. The risk of misplaced samples can be reduced by distinguishing the sample tray.

Software can Excel To extract information such as "Sample Name", "Weight" and "Solvent Volume", just click "Load Sample Table". Suitable for users who need to manage table data separately.

Cu Absorption wavelength and Ni The absorption wavelength is very close, even when the analysis contains a large amount of Ni tiny amounts in the electroplating solution Cu, The polarization Zeeman calibration method can also perform high-precision measurement.

ZA4700 It is a special machine for graphite furnaces, which can provide background correction for all processes such as drying, ashing, atomization, removal and cooling of samples during the measurement process. It provides important information for the determination conditions for creating complex matrix samples.
Background monitoring of the drying and ashing stage can be performed using the polarization Zeeman correction method of permanent magnets.
In the determination of magnesium, when the ashing temperature increases, it can be seen that magnesium volatilizes during the ashing process (left picture).
When the ashing temperature decreases and the volatile signal disappears, a signal with good reproducibility can be obtained (Picture right ) 。

The following figure shows the use ZA4800 An example of 6 elements being measured continuously. Use composite lamps together, lit up 6 element lamps at the same time, and switch the wavelength of each sample for measurement. Using polarization Zeman's unique baseline stability and continuous measurement can greatly improve the analysis efficiency. In addition, the frequency of sample replacement can be reduced, thereby reducing the burden on the operator.


model | ZA4000 | ZA4800 | ZA4300 | ZA4700 |
Analysis | Flame method & graphite furnace method | Flame method (fast continuous) | Flame method | Graphite furnace method |
Determination mode | Flame & Graphite Furnace | flame | flame | Graphite furnace |
Light Road | Real-time dual beam | |||
Background correction method | flame /Graphite furnace integrated machine: Polarization Zeeman calibration method | Zeeman background correction method | ||
Number of installed lights | 8(Tower wheel mode) | 8(Tower wheel mode) | 8(Tower wheel mode) | 8(Tower wheel mode) |