Product/Brand

Liquid Chromatography
Hiraki UHPLC Chromatography column LaChromUltraII C18
Price:Discuss personally

WeChat

Brand:HITACHI
Model:LaChromUltraII C18
Inventory Status:Spot promotion/please call for consultation
Contact:
Tel:+86 010-51660436
Email:dnyc_sales@163.com
Details Documentation Related

It has both super durability, ultra-high pressure resistance and high separation performance.
UHPLC The application range extends from ultra-high speed analysis to ultra-high separation analysis.

LaChromUltra II Inorganic-organic composite silicon material with higher physical and chemical resistance than the original silicone particles is used. Hitachi Hi-Tech Special launches particle size 1.9 µm、 250 long mm Chromatographic column, fully utilize UHPLC high voltage resistance.
therefore, UHPLC The scope of application has also expanded from ultra-high speed analysis to high separation analysis.

Features

It uses an inorganic-organic composite silicon material with higher physical and chemical resistance than the original silicone particles, and has excellent pressure resistance. Users can choose 250 mm Chromatographic column. The theoretical number of trays is as high as 50,000, which can give full play to the advantages in the analysis of relevant substances and multi-components.
And, if two 250 are used mm The theoretical number of chromatographic columns can reach an ultra-high resolution of 100,000.

LaChromUltra II C18(1.9 µm) Determination example Sample: uracil Methyl benzoate Naphthalene Butyl benzoate

LaChromUltraII C18111.png

Analysis conditions:

Mobile phase

(1)(2)60% CH3CN
(3)(4)70% CH
3CN

Column temperature

40℃

Detect wavelength

UV 270 nm

Injection volume

(1)(2)1 µL
(3)(4)2 µL

instrument

· Hitachi Ultra-High Performance Liquid Chromatography ChromasterUltra Rs

Technical parameters

name

Particle size ( µm)

Column size ( mm I.D. × mm L.)

LaChromUltra II C18(1.9 µm)
Filler properties and LaChrom II C18 same.
Super high speed LC With the regular LC Methods are easily converted.

1.9

2 ×50

2 ×100

2 ×150

3 ×50

3 ×100

3 ×150

3 ×250

4.6 ×250

 

name

Particle size ( µm)

Column size ( mm I.D. × mm L.)

LaChrom II C18
Filler properties and LaChromUltra II C18 same.
Super high speed LC With the regular LC Methods are easily converted.

3

4.6 ×100

4.6 ×150

5

4.6 ×150

4.6 ×250