Product/Brand

Syringe Pump
Lange integrated laboratory syringe pump LSP01-3A
Price:¥10260

WeChat

Brand:LONGER
Model:LSP01-3A
Inventory Status:Spot promotion/please call for consultation
Contact:
Tel:+86 010-51660436
Email:dnyc_sales@163.com
Details Documentation Related

Applicable places:

Biological laboratory use


Product Features:

Micro-syringe pump LSP01-1A It is a single-channel perfusion injection pump, mainly used in biological laboratories, with an integrated structure. Can hold syringes with different specifications (Sampler ), LSP01-1A Micro-syringe pumps are suitable for high-precision and small flow of liquid transmission.

Functional Features

LSP01-1A Syringe inner diameter input function: You can select the syringe from the list or directly enter the syringe inner diameter
The micro-syringe pump has a friendly human-machine interface: large-screen LCD display, digital knobs are used in conjunction with film buttons, easy to operate and quick
Working mode: Single push working mode
Power-down memory function: 1. EEPROM Save the settings parameters and after powering up again, there is no need to reset it. 2. Power off during operation in flow mode. After power-on recovery, you can continue to run or stop according to the set parameters.
Traffic jam protection function: When the propulsion mechanism of the syringe pump is blocked during work, the syringe pump will stop the operation of the propulsion mechanism and issue a whistle alarm.
The 485 communication bus can be connected to the upper computer and controlled by the background software.
External control interface: with input /Output control function
Fluid calibration function: More accurate flow can be obtained through calibration procedures
Syringe protection function: By adjusting the position of the limit block, the syringe can be prevented from being damaged.


Technical Indicators

Micro-syringe pump working mode: injection
Number of channels: 1
Maximum itinerary: 140 mm
Travel resolution: 0.156 μm
Linear speed range: 5 μm/min-65mm/min(flow =Linear speed ×Internal cross-sectional area of the syringe )
Linear speed adjustment resolution: 5 μm/min
Stroke control accuracy: Error ≤±0.5%(journey ≥When the maximum itinerary is 30% )
Rated linear thrust: >90N
Syringe selection: built-in main manufacturers and main models of syringes for selection
Syringe customization: can be directly input into the syringe
Flow calibration: Get more accurate liquid volume through the calibration procedure
Operation parameter settings: dispensing liquid volume, injection time, etc.
Display parameter selection: liquid volume, flow rate or linear speed
Power down memory: After powering on again, you can choose whether to continue working according to the state before power down.
Status signal output: 2 channels OC Gate signal output, used to indicate activation /Stop and direction status
Control signal input: 2 start-stop control inputs, 1 fallen edge trigger signal control start-stop; 1 way TTL Level signal control start and stop
Communication interface: RS485
Dimensions: 280 ×210×140(mm)
Weight: 3.6 kg
Use power supply: AC 90V-260V/15W
Working ambient temperature: 0 ℃-40℃
Relative humidity of the working environment: <80%


Micro-syringe pump model

Product number

Applicable syringe specifications

Suitable for syringe internal meridian (mm)

Reference flow range (μl/min-ml/min)  

LSP01-1A

05.03.40A

10μl

0.50

0.001-0.0128

25μl

0.80

0.0025-0.0327

50μl

1.10

0.0048-0.0618

100μl

1.60

0.0101-0.1307

250μl

2.30

0.0208-0.2701

500μl

3.25

0.0415-0.5392

1ml

4.72

0.0875-1.1373

2ml

9.00

0.3181-4.1351

5ml

13.10

0.6739-8.7608

10ml

16.60

1.0821-14.068

20ml

19.00

1.4176-18.429

30ml

23.00

2.0774-27.006

60ml

29.14

3.3346-43.349


  • Tel:+86 010-51660436
  • Zip code:10000
  • Email:dnyc_sales@163.com
  • Address:4th Floor, East Side, Building A6, Area A, No. 80 Xingshikou Road, Haidian District, Beijing