Lange split laboratory syringe pump TJ-1A/L0107-1A
Price:Discuss personally

Applicable places:
Biological laboratory use
Product Features:
Precision syringe pump LSP01-2A It is a single-channel perfusion injection pump, mainly used in biological laboratories, with an integrated structure. Can hold syringes with different specifications (Sampler ), LSP01-2A Precision syringe pumps are suitable for high-precision and small flow of liquid transmission.
Functional Features
LSP01-2A Syringe inner diameter input function: You can select the syringe from the list or directly enter the syringe inner diameter
Human-computer interface: large-screen LCD display, digital knobs are used in conjunction with film buttons, easy to operate and quick
Working mode: Single push working mode
Power-down memory function: 1. EEPROM Save the settings parameters and after powering up again, there is no need to reset it. 2. Power off during operation in flow mode. After power-on recovery, you can continue to run or stop according to the set parameters.
Traffic jam protection function: When the propulsion mechanism of the syringe pump is blocked during work, the syringe pump will stop the operation of the propulsion mechanism and issue a whistle alarm.
The 485 communication bus can be connected to the upper computer and controlled by the background software.
External control interface: with input /Output control function
Fluid calibration function: More accurate flow can be obtained through calibration procedures
Syringe protection function: By adjusting the position of the limit block, the syringe can be prevented from being damaged.
LSP01-2A Precision syringe pump and LSP01-1A Compare:
LSP01-2A Increase 5 times faster speed reduction pulsation less
LSP01-2A More suitable for cell analysis
LSP01-2A Precision syringe pumps are more suitable for transporting small flows of liquids
Technical Indicators
Precision syringe pump SLP01-2A Working mode: Injection
Number of channels: 1
Maximum itinerary: 140 mm
Stroke resolution: 0.03125 μm
Linear speed range: 1 μm/min-13mm/min(flow =Linear speed ×Internal cross-sectional area of the syringe )
Linear speed adjustment resolution: 1 μm/min
Stroke control accuracy: Error ≤±0.5%(journey ≥When the maximum itinerary is 30% )
Rated linear thrust: >90N
Syringe selection: built-in main manufacturers and main models of syringes for selection
Syringe customization: can be directly input into the syringe
Flow calibration: Get more accurate liquid volume through the calibration procedure
Operation parameter settings: dispensing liquid volume, injection time, etc.
Display parameter selection: liquid volume, flow rate or linear speed
Power down memory: After powering on again, you can choose whether to continue working according to the state before power down.
Status signal output: 2 channels OC Gate signal output, used to indicate activation /Stop and direction status
Control signal input: 2 start-stop control inputs, 1 fallen edge trigger signal control start-stop; 1 way TTL Level signal control start and stop
Communication interface: RS485
Dimensions: 280 ×210×140(mm)
Weight: 3.6 kg
Use power supply: AC 90V-260V/15W
Working ambient temperature: 0 ℃-40℃
Relative humidity of the working environment: <80%
Syringe pump model | Product number | Applicable syringe specifications | Suitable for syringe internal meridian (mm) | Reference flow range (μl/min-ml/min) |
LSP01-2A | 05.03.41A | 10μl | 0.50 | 0.0002-0.0026 |
25μl | 0.80 | 0.0005-0.0065 | ||
50μl | 1.10 | 0.0095-0.0124 | ||
100μl | 1.60 | 0.002-0.026 | ||
250μl | 2.30 | 0.0042-0.054 | ||
500μl | 3.25 | 0.0083-0.1078 | ||
1ml | 4.72 | 0.0175-0.2275 | ||
2ml | 9.00 | 0.0636-0.827 | ||
5ml | 13.10 | 0.1348-1.7522 | ||
10ml | 16.60 | 0.2164-2.8135 | ||
20ml | 19.00 | 0.2835-3.6859 | ||
30ml | 23.00 | 0.4155-5.4012 | ||
60ml | 29.14 | 0.6669-8.6699 |