Lange split laboratory syringe pump TJ-1A/L0107-1A
Price:Discuss personally

Applicable places:
Biological laboratory use
Product Features:
High pressure syringe pump LSP01-1BH 10 card can be installed ul-100ml Specifications of syringes (Sampler ),The high-pressure syringe pump's super-thrust is suitable for the transmission of viscous liquids and chemical reactor experiments.
Functional Features
LSP01-1BH High pressure syringe pump can select the syringe from the list or directly enter the syringe inner diameter to determine the syringe
Large-screen LCD display, digital knobs and film buttons are intuitive, simple and fast
Working mode: 5 working modes (perfusion /Draw /Perfusion first and then extraction /Draw first and then inject /Continuous work )
Power-down memory function: 1. EEPROM Save the settings parameters, after powering on again, there is no need to reset 2. Power off during operation in flow mode. After powering on, you can continue to run or stop according to the set parameters.
Traffic jam protection function: When the propulsion mechanism of the syringe pump is blocked during work, the syringe pump will stop the operation of the propulsion mechanism and issue a whistle alarm.
Using 485 communication bus can be connected to the upper computer and control it through the background.
External control interface: Input /Output control function
Fluid calibration function: More accurate flow can be obtained through calibration procedures
Syringe protection function: By adjusting the position of the limit block, the syringe can be protected from damage
Technical Indicators
High-pressure syringe pump working mode: injection, draw, injection first, then draw, first draw, then injection, continuous
Number of channels: 1
Maximum itinerary: 140 mm
Travel resolution: 0.156 μm
Linear speed range: 5 μm/min-130mm/min
Linear speed adjustment resolution: 5 μm/min
Stroke control accuracy: Error ≤±0.5%(journey ≥When the maximum itinerary is 30% )
High pressure syringe pump rated linear thrust: >450N
Syringe selection: built-in main manufacturers and main models of syringes for selection
Syringe customization: can be directly input into the syringe
Flow calibration: Get more accurate liquid volume through the calibration procedure
Operation parameter settings: injection volume, injection time, extraction time, etc.
Display parameter selection: liquid volume, flow rate or linear speed
Power down memory: Keep the parameter settings before power down after powering up again
Status signal output: 2 channels OC Gate signal output, used to indicate activation /Stop and direction status
Control signal input: 2 start-stop control inputs, 1 fallen edge trigger signal control start-stop; 1 way TTL Level signal control start and stop
Communication interface: RS485
Dimensions: 280 ×250×140(mm)
Weight: 6.3 kg
Use power supply: AC 90V-260V/25W
Working ambient temperature: 0 ℃-40℃
Relative humidity of the working environment: <80%
Syringe pump model | Product number | Applicable syringe specifications (ml) | Syringe inner meridian (mm) | Reference flow range (μl/min-ml/min) | Maximum outlet pressure (Mpa) |
LSP01-1BH | 05.03.43A | 2.5 | 4.79 | 0.0901-2.3426 | 19.48 |
8 | 9.53 | 0.3567-9.2730 | 5.05 | ||
20 | 19.13 | 1.4371-37.3648 | 1.25 | ||
50 | 28.6 | 3.2121-83.5152 | 0.56 | ||
100 | 34.9 | 4.7831-124.361 | 0.37 |