Case

Food Safety Testing: Challenges and Analytical Solutions

Views: Updated:2025-05-13

Critical Industry Challenges:

Food safety testing encounters multifaceted complexities:

Diverse Analytical Targets:

Matrices span raw ingredients, processed goods, and finished products, requiring analysis of nutrients, illegal additives, pesticide residues, veterinary drug residues, heavy metals, and microbiological contaminants.

Evolving Regulatory Stringency:

Continuously updated domestic and international standards demand enhanced analytical precision with lower detection limits.

Matrix Interference Complexity:

Heterogeneous sample compositions create analytical interference challenges, necessitating advanced sample preparation and detection methodologies.

Throughput Demands:

Rapid market circulation requires accelerated turnaround of accurate analytical reports.

Data Integrity Requirements:

Strict traceability and reliability mandates for complete, auditable testing data.


Integrated Analytical Solutions:

Hitachi High-Tech's Chromaster UHPLC systems deliver exceptional performance for precise food component quantification.

Shanghai Yidian Analytical's S12 Multi-Parameter Food Safety Analyzer offers operational flexibility and high accuracy for diverse contaminant detection.

Shanghai Rex Instrument's graphite digestion systems (KDNX-20) and automated Kjeldahl nitrogen analyzers (KDN-1) excel in sample preparation and protein determination.

Shanghai Boxun's BSC-250 incubators provide stable environmental control for microbiological culturing.

食品检测.png


Instrumentation Specifications and Advantages:


Hitachi Chromaster Advanced UHPLC System

Manufacturer Profile: Global leader with 50 years of chromatography expertise

Technical Specifications:

40 MPa or 60 MPa operational pressure options

Modular column switching valves

Customizable reaction modules

Application Suitability: Complex matrix analysis

image.png


Yidian Analytical S12 Multi-Parameter Food Safety Analyzer

Optical System:

Ratio double-beam optical path

High-performance holographic grating monochromator

Ultra-low stray light (< 0.015%)

Operational Interface: 7-inch color touch LCD

Detection Capabilities: Formaldehyde, sodium formaldehyde sulfoxylate, and multiple contaminants

image.png


Rex Instrument Specialized Sample Preparation Systems

KDNX-20 Graphite Digestion System:

Advanced uniform heating technology

Rapid digestion for complex food matrices

KDN-1 Automated Kjeldahl Analyzer:

Integrated alkali/acid addition modules

Automated distillation and titration

Precision: ≤0.2% RSD

image.png

image.png


Boxun BSC-250 Constant Temperature/Humidity Incubator

Environmental Control:

Dual-regulation heating/cooling system

Temperature stability: ±0.5°C

Humidity range: 40-95% RH

Microbiological Applications:

Static cultivation of bacteria, molds, fungi

Long-term sample preservation

Compliance: Meets ISO 17025 and FDA BAM protocols

image.png


Equipment selection should be optimized according to experimental scale. For parameter compatibility validation, please consult our technical team.