Product/Brand

Water Purification System
Shanghai Lei Magnetic Ultrapure Water System UPW-N30UV
Price:¥21800

WeChat

Brand:lei-ci
Model:UPW-N30UV
Inventory Status:Spot promotion/please call for consultation
Contact:
Tel:+86 010-51660436
Email:dnyc_sales@163.com
Details Documentation Related

UPW Series of laboratory pure water systems

——Complete models to meet different needs

——Integrated design, ready to use with water

——Quick plug-in pipe connection for easy maintenance

——Double column extended filter element for longer service life

——Real-time monitoring of sensors to ensure stable water quality

——LCD Display water quality information and water use information in real time

——Supports water quality alarm and water leakage alarm

 

【Model selection]

series

Water inlet

Out of water

Water production rate

SLR osmosis membrane

15L/h

Double reverse osmosis membrane

30L/h

Two-stage reverse osmosis

15L/h

UPW-N

Tap water

Pure water; Ultrapure water

UPW-N15UV

UPW-N30UV

UPW-N2-15UV

UPW-P

Pure water

Ultrapure water

UPW-P (1.5-2 L/min)

UPW-H

Tap water

Pure water, high-purity water

UPW-H15

UPW-H30

UPW-H2-15

UPW-R

Tap water

Pure water

UPW-R15

UPW-R30

UPW-R2-15

 

 

Functional structure

UPW-N

UPW-P

UPW-H

UPW-R

Pretreatment column


High pressure pump

Reverse Osmosis Assembly


Purification column


Ultrapure column



Single wavelength UV lamp




Double wavelength UV lamp



Microfilter column


2G Pressure water tank


Terminal filter



Water leakage protection probe


 

Built-in pretreatment column

Carbon-containing filter element, effectively removes free activated chlorine from source water;

Include PP Cotton filter element effectively removes solid particles and other impurities, protects RO The membrane is not blocked;

The pretreatment column is built-in, saving space and more convenient to use.

 

High-performance reverse osmosis membrane

Single membrane, double membrane, and two-stage reverse osmosis membrane are available in various forms to meet different needs;

The high-performance Dow reverse osmosis membrane can effectively remove inorganic ions, bacteria and small solid particles, and have a long service life.

 

Purification column / Ultrapure column

Double column design, large resin loading and long service life;

The purification column uses high-quality precision resin, with high exchange efficiency and stable effluent water quality.

Ultrapure columns are made of nuclear-grade polishing resin, which has higher exchange efficiency and is prepared 18.2 M Ω.cm Ultrapure water.

 

High power single wave / Double wave ultraviolet light

Single wave ultraviolet lamp (254 nm) It can kill bacteria and other microorganisms, improve water quality while preventing microorganisms from growing.

Double wave ultraviolet lamp (185 nm and 254 nm), While killing bacteria and other microorganisms, it effectively degrades organic matter and reduces TOC content.

 

Conductance sensor

Three sets of conductivity sensors are installed, including a set of dedicated conductivity sensors for pure water systems with temperature compensation function (electrode constant is 0.01), which comprehensively monitors the operation and water quality changes of pure water systems.

 

Built-in pressure water tank

While reducing the space occupied by the laboratory, it improves the water production efficiency of pure water systems.

 

Front-end filter

0.22 um The filter membrane removes the source water and trace impurities left over from the process, further improving the water quality.

 

Water leakage protection

With a water leakage detection sensor, it can automatically alarm and adjust the instrument to enter standby state in emergencies.

 

【Technical parameters]

UPW-R Series pure water system

model

UPW-R15

UPW-R30

UPW-R2-15

Water inlet and outlet

Water inlet

Tap water (conductivity <400 μs/cm)

Inlet water temperature

5-40℃

Water inlet pressure

0.1-0.5 Mpa

Water quality

Pure water

Pure water indicators

Water production rate

15 L/h

30 L/h

15  L/h

Conductivity

<20 μs/cm

<5 μs/cm

Desalination rate

95-99%

>99%

Bacterial removal rate

>99%

Main structure

Pretreatment column

have

have

have

High pressure pump

have

have

have

Reverse Osmosis Assembly

Single film

Double membrane

Secondary reverse osmosis

Purification column

-

-

-

Single wavelength UV lamp

-

-

-

Ultrapure column

-

-

-

Double wavelength UV lamp

-

-

-

Microfilter column

-

-

-

2G Pressure water tank

have

have

have

Terminal filter

-

-

-

Water leakage protection probe

have

have

have

Standard configuration

*Host


*Pretreatment column

REX-SP101

*High pressure pump

REX-SP605/607/609

*Reverse osmosis column

REX-SP202

*Built-in 2 G Pressure water tank

REX-SP413

*Water leakage protection probe

REX-SP846

 

 

UPW-H Series high-purity water system

model

UPW-H15

UPW-H30

UPW-H2-15

Water inlet and outlet

Inlet water quality

Tap water (conductivity <400 μs/cm)

Inlet water temperature

5-40℃

Water inlet pressure

0.1-0.5 Mpa

Water quality

Pure water, high-purity water

Pure water indicators

Water production rate

15 L/h

30 L/h

15  L/h

Conductivity

<20  μs/cm

<5  μs/cm

Desalination rate

95-99%

>99%

Bacterial removal rate

>99%

High purity water index

Resistivity 25 ℃

>10 MΩ

Bacterial removal rate

>99%

TOC

<30 ppb

Particulate matter ( ≥0.22 μm)

<1 pc/ml

bacteria

<1 cfu/ml

Main structure

Pretreatment column

have

have

have

High pressure pump

have

have

have

Reverse Osmosis Assembly

Single film

Double membrane

Secondary reverse osmosis

Purification column

have

have

have

Single wavelength UV lamp

have

have

have

Ultrapure column

-

-

-

Double wavelength UV lamp

-

-

-

Microfilter column

have

have

have

2G Pressure water tank

have

have

have

Terminal filter

-

-

-

Water leakage protection probe

have

have

have

Standard configuration

*Host


*Pretreatment column

REX-SP101

*High pressure pump

REX-SP605/607/609

*Reverse osmosis column

REX-SP202

*Purification column

REX-SP301

*Single wavelength 254 nm UV lamp

REX-SPMWUV-1

*Microfilter column

REX-SP502B

*Built-in 2 G Pressure water tank

REX-SP413

*Water leakage protection probe

REX-SP846

Water inlet TOC Less than 1000 ppb

 

 

UPW-N Series ultrapure water system

model

UPW-N15UV

UPW-N30UV

UPW-N2-15UV

Water inlet and outlet

Inlet water quality

Tap water (conductivity <400 μs/cm)

Inlet water temperature

5-40℃

Water inlet pressure

0.1-0.5 Mpa

Water quality

Pure water, ultrapure water

Pure water indicators

Water production rate

15 L/h

30 L/h

15  L/h

Conductivity

<20  μs/cm

<5  μs/cm

Desalination rate

95-99%

>99%

Bacterial removal rate

>99%

Ultrapure water index

Resistivity 25 ℃

18.2 MΩ

Conductivity 25 ℃

0.055 μs/cm

Flow rate

1.5-2 L/min

TOC

<10 ppb

Particulate matter ( ≥0.22 μm)

<1 pc/ml

bacteria

<1 cfu/ml

Main structure

Pretreatment column

have

have

have

High pressure pump

have

have

have

Reverse Osmosis Assembly

Single film

Double membrane

Secondary reverse osmosis

Purification column

have

have

have

Single wavelength UV lamp

-

-

-

Ultrapure column

have

have

have

Double wavelength UV lamp

have

have

have

Microfilter column

have

have

have

2G Pressure water tank

have

have

have

Terminal filter

have

have

have

Water leakage protection probe

have

have

have

Standard configuration

*Host


*Pretreatment column

REX-SP101

*High pressure pump

REX-SP605/607/609

*Reverse osmosis column

REX-SP202

*Purification column

REX-SP301

*Ultrapure column

REX-SP302

*Double wavelength 254 /185nm UV lamp

REX-SPDWUV-1B

*Microfilter column

REX-SP502B

*Built-in 2 G Pressure water tank

REX-SP413

* Terminal filter

REX-SP504

*Water leakage protection probe

REX-SP846

Water inlet TOC Less than 1000 ppb;

 

UPW-P Series ultrapure water system

model

UPW-P

Water inlet and outlet

Inlet water quality

Pure water (Conductivity <20 μs/cm)

Inlet water temperature

5-40℃

Water inlet pressure

-

Water quality

Ultrapure water

Ultrapure water index

Resistivity 25 ℃

18.2 MΩ

Conductivity 25 ℃

0.055 μs/cm

Flow rate

1.5-2 L/min

TOC

<10 ppb

Particulate matter ( ≥0.22 μm)

<1 pc/ml

bacteria

<1 cfu/ml

Main structure

Pretreatment column

-

High pressure pump

have

Reverse Osmosis Assembly

-

Purification column

have

Single wavelength UV lamp

-

Ultrapure column

have

Double wavelength UV lamp

have

Microfilter column

have

2G Pressure water tank

-

Terminal filter

have

Water leakage protection probe

-

Standard configuration

*Host


*High pressure pump

REX-SP608

*Purification column

REX-SP301

*Ultrapure column

REX-SP302

*Double wavelength 254 /185nm UV lamp

REX-SPDWUV-1B

*Microfilter column

REX-SP502B

*Terminal filter

REX-SP504

Water inlet TOC Less than 50 ppb

 

  • Tel:+86 010-51660436
  • Zip code:10000
  • Email:dnyc_sales@163.com
  • Address:4th Floor, East Side, Building A6, Area A, No. 80 Xingshikou Road, Haidian District, Beijing
  • Subscription number
  • WeChat Mini Program
  • SimplabCopyright 京ICP备09066698号-16