Shanghai Leici Pure Water System UPW-R30
Price:Discuss personally

UPW Series of laboratory pure water systems
——Complete models to meet different needs
——Integrated design, ready to use with water
——Quick plug-in pipe connection for easy maintenance
——Double column extended filter element for longer service life
——Real-time monitoring of sensors to ensure stable water quality
——LCD Display water quality information and water use information in real time
——Supports water quality alarm and water leakage alarm
【Model selection]
series | Water inlet | Out of water | Water production rate | ||
SLR osmosis membrane 15L/h | Double reverse osmosis membrane 30L/h | Two-stage reverse osmosis 15L/h | |||
UPW-N | Tap water | Pure water; Ultrapure water | UPW-N15UV | UPW-N30UV | UPW-N2-15UV |
UPW-P | Pure water | Ultrapure water | UPW-P (1.5-2 L/min) | ||
UPW-H | Tap water | Pure water, high-purity water | UPW-H15 | UPW-H30 | UPW-H2-15 |
UPW-R | Tap water | Pure water | UPW-R15 | UPW-R30 | UPW-R2-15 |
Functional structure | UPW-N | UPW-P | UPW-H | UPW-R |
Pretreatment column | ● | ● | ● | |
High pressure pump | ● | ● | ● | ● |
Reverse Osmosis Assembly | ● | ● | ● | |
Purification column | ● | ● | ● | |
Ultrapure column | ● | ● | ||
Single wavelength UV lamp | ● | |||
Double wavelength UV lamp | ● | ● | ||
Microfilter column | ● | ● | ● | |
2G Pressure water tank | ● | ● | ● | |
Terminal filter | ● | ● | ||
Water leakage protection probe | ● | ● | ● |
Built-in pretreatment column
Carbon-containing filter element, effectively removes free activated chlorine from source water;
Include PP Cotton filter element effectively removes solid particles and other impurities, protects RO The membrane is not blocked;
The pretreatment column is built-in, saving space and more convenient to use.
High-performance reverse osmosis membrane
Single membrane, double membrane, and two-stage reverse osmosis membrane are available in various forms to meet different needs;
The high-performance Dow reverse osmosis membrane can effectively remove inorganic ions, bacteria and small solid particles, and have a long service life.
Purification column / Ultrapure column
Double column design, large resin loading and long service life;
The purification column uses high-quality precision resin, with high exchange efficiency and stable effluent water quality.
Ultrapure columns are made of nuclear-grade polishing resin, which has higher exchange efficiency and is prepared 18.2 M Ω.cm Ultrapure water.
High power single wave / Double wave ultraviolet light
Single wave ultraviolet lamp (254 nm) It can kill bacteria and other microorganisms, improve water quality while preventing microorganisms from growing.
Double wave ultraviolet lamp (185 nm and 254 nm), While killing bacteria and other microorganisms, it effectively degrades organic matter and reduces TOC content.
Conductance sensor
Three sets of conductivity sensors are installed, including a set of dedicated conductivity sensors for pure water systems with temperature compensation function (electrode constant is 0.01), which comprehensively monitors the operation and water quality changes of pure water systems.
Built-in pressure water tank
While reducing the space occupied by the laboratory, it improves the water production efficiency of pure water systems.
Front-end filter
0.22 um The filter membrane removes the source water and trace impurities left over from the process, further improving the water quality.
Water leakage protection
With a water leakage detection sensor, it can automatically alarm and adjust the instrument to enter standby state in emergencies.
【Technical parameters]
UPW-R Series pure water system
model | UPW-R15 | UPW-R30 | UPW-R2-15 |
Water inlet and outlet | |||
Water inlet | Tap water (conductivity <400 μs/cm) | ||
Inlet water temperature | 5-40℃ | ||
Water inlet pressure | 0.1-0.5 Mpa | ||
Water quality | Pure water | ||
Pure water indicators | |||
Water production rate | 15 L/h | 30 L/h | 15 L/h |
Conductivity | <20 μs/cm | <5 μs/cm | |
Desalination rate | 95-99% | >99% | |
Bacterial removal rate | >99% | ||
Main structure | |||
Pretreatment column | have | have | have |
High pressure pump | have | have | have |
Reverse Osmosis Assembly | Single film | Double membrane | Secondary reverse osmosis |
Purification column | - | - | - |
Single wavelength UV lamp | - | - | - |
Ultrapure column | - | - | - |
Double wavelength UV lamp | - | - | - |
Microfilter column | - | - | - |
2G Pressure water tank | have | have | have |
Terminal filter | - | - | - |
Water leakage protection probe | have | have | have |
Standard configuration | |||
*Host | |||
*Pretreatment column | REX-SP101 | ||
*High pressure pump | REX-SP605/607/609 | ||
*Reverse osmosis column | REX-SP202 | ||
*Built-in 2 G Pressure water tank | REX-SP413 | ||
*Water leakage protection probe | REX-SP846 | ||
UPW-H Series high-purity water system
model | UPW-H15 | UPW-H30 | UPW-H2-15 |
Water inlet and outlet | |||
Inlet water quality | Tap water (conductivity <400 μs/cm) | ||
Inlet water temperature | 5-40℃ | ||
Water inlet pressure | 0.1-0.5 Mpa | ||
Water quality | Pure water, high-purity water | ||
Pure water indicators | |||
Water production rate | 15 L/h | 30 L/h | 15 L/h |
Conductivity | <20 μs/cm | <5 μs/cm | |
Desalination rate | 95-99% | >99% | |
Bacterial removal rate | >99% | ||
High purity water index | |||
Resistivity 25 ℃ | >10 MΩ | ||
Bacterial removal rate | >99% | ||
TOC | <30 ppb | ||
Particulate matter ( ≥0.22 μm) | <1 pc/ml | ||
bacteria | <1 cfu/ml | ||
Main structure | |||
Pretreatment column | have | have | have |
High pressure pump | have | have | have |
Reverse Osmosis Assembly | Single film | Double membrane | Secondary reverse osmosis |
Purification column | have | have | have |
Single wavelength UV lamp | have | have | have |
Ultrapure column | - | - | - |
Double wavelength UV lamp | - | - | - |
Microfilter column | have | have | have |
2G Pressure water tank | have | have | have |
Terminal filter | - | - | - |
Water leakage protection probe | have | have | have |
Standard configuration | |||
*Host | |||
*Pretreatment column | REX-SP101 | ||
*High pressure pump | REX-SP605/607/609 | ||
*Reverse osmosis column | REX-SP202 | ||
*Purification column | REX-SP301 | ||
*Single wavelength 254 nm UV lamp | REX-SPMWUV-1 | ||
*Microfilter column | REX-SP502B | ||
*Built-in 2 G Pressure water tank | REX-SP413 | ||
*Water leakage protection probe | REX-SP846 | ||
Water inlet TOC Less than 1000 ppb
UPW-N Series ultrapure water system
model | UPW-N15UV | UPW-N30UV | UPW-N2-15UV |
Water inlet and outlet | |||
Inlet water quality | Tap water (conductivity <400 μs/cm) | ||
Inlet water temperature | 5-40℃ | ||
Water inlet pressure | 0.1-0.5 Mpa | ||
Water quality | Pure water, ultrapure water | ||
Pure water indicators | |||
Water production rate | 15 L/h | 30 L/h | 15 L/h |
Conductivity | <20 μs/cm | <5 μs/cm | |
Desalination rate | 95-99% | >99% | |
Bacterial removal rate | >99% | ||
Ultrapure water index | |||
Resistivity 25 ℃ | 18.2 MΩ | ||
Conductivity 25 ℃ | 0.055 μs/cm | ||
Flow rate | 1.5-2 L/min | ||
TOC | <10 ppb | ||
Particulate matter ( ≥0.22 μm) | <1 pc/ml | ||
bacteria | <1 cfu/ml | ||
Main structure | |||
Pretreatment column | have | have | have |
High pressure pump | have | have | have |
Reverse Osmosis Assembly | Single film | Double membrane | Secondary reverse osmosis |
Purification column | have | have | have |
Single wavelength UV lamp | - | - | - |
Ultrapure column | have | have | have |
Double wavelength UV lamp | have | have | have |
Microfilter column | have | have | have |
2G Pressure water tank | have | have | have |
Terminal filter | have | have | have |
Water leakage protection probe | have | have | have |
Standard configuration | |||
*Host | |||
*Pretreatment column | REX-SP101 | ||
*High pressure pump | REX-SP605/607/609 | ||
*Reverse osmosis column | REX-SP202 | ||
*Purification column | REX-SP301 | ||
*Ultrapure column | REX-SP302 | ||
*Double wavelength 254 /185nm UV lamp | REX-SPDWUV-1B | ||
*Microfilter column | REX-SP502B | ||
*Built-in 2 G Pressure water tank | REX-SP413 | ||
* Terminal filter | REX-SP504 | ||
*Water leakage protection probe | REX-SP846 | ||
Water inlet TOC Less than 1000 ppb;
UPW-P Series ultrapure water system
model | UPW-P |
Water inlet and outlet | |
Inlet water quality | Pure water (Conductivity <20 μs/cm) |
Inlet water temperature | 5-40℃ |
Water inlet pressure | - |
Water quality | Ultrapure water |
Ultrapure water index | |
Resistivity 25 ℃ | 18.2 MΩ |
Conductivity 25 ℃ | 0.055 μs/cm |
Flow rate | 1.5-2 L/min |
TOC | <10 ppb |
Particulate matter ( ≥0.22 μm) | <1 pc/ml |
bacteria | <1 cfu/ml |
Main structure | |
Pretreatment column | - |
High pressure pump | have |
Reverse Osmosis Assembly | - |
Purification column | have |
Single wavelength UV lamp | - |
Ultrapure column | have |
Double wavelength UV lamp | have |
Microfilter column | have |
2G Pressure water tank | - |
Terminal filter | have |
Water leakage protection probe | - |
Standard configuration | |
*Host | |
*High pressure pump | REX-SP608 |
*Purification column | REX-SP301 |
*Ultrapure column | REX-SP302 |
*Double wavelength 254 /185nm UV lamp | REX-SPDWUV-1B |
*Microfilter column | REX-SP502B |
*Terminal filter | REX-SP504 |
Water inlet TOC Less than 50 ppb
Price:Discuss personally
Price:Discuss personally
Price:Discuss personally
Price:Discuss personally
Price:Discuss personally
Subscription number
WeChat Mini ProgramSimplabCopyright 京ICP备09066698号-16