 Master-R The series of double-stage reverse osmosis ultrapure water machines are based on the standard double-stage reverse osmosis process: dual pump and double membrane +Intermediate water tank, laboratory pure water preparation system for manufacturing. In the working conditions where the water quality of the source water is poor,


RO The water-producing conductivity can also be stable at 1-5 μs/cm, With single level RO system Compared with the water production quality, the consumables in the post-purification unit are cheaper, and the two-stage level with simple packaging RO system (Single pump double membranes


Intermediate water tank )Compared with the design, the design is more reasonable and the water production quality is more stable.

 

 

Features and Advantages

■ Fully automatic microcomputer control system, multi-level menu operation


■ Extra large backlit LCD LCD screen (Resolution: 240 ×128,Size: 106 ×57mm),


    Real-time animation working mode display throughout the whole process

 

■ Domestic unique ultrapure water full-line disinfection program, just add disinfection tablets to start


     Key disinfection procedure to ensure high-quality pure water

 

■ Fully automatic RO Membrane anti-scaling flushing procedure, extended RO Membrane service life


■ none water Call the police, water Full alarm, source water 、RO water /Highly pure water 、Super pure water (Parameters can be set at will )Alarm beyond the standard

 

■ Consumable end-of-life alarm, automatic fault detection, and provide safety assurance

 

■ Ultrapure water circulation system that can be started and closed freely to maintain the system's low bacterial contamination level

 

■ Special factory and customer secondary passwords, system settings are protected by passwords to prevent unauthorized changes

 

■ Can set preprocessing, RO membrane, UV Lifespan of lamps and ultrapure columns, showing the use of consumables and the remaining time

 

■ Automatic reminder to replace consumables when expiration to avoid degradation of water quality

 

■ Special setting of fixed quality water withdrawal function (Timing: 1-99 min; Qualification: 0.1-18.2 MΩ.cm)

 

■ The unique working modes of work and get off work in China ensure sufficient water supply

 

■ Various specifications of water storage buckets are available to meet different needs

 

■ Integrated plastic molded chassis, ergonomic design, composite GLP specification

 

■ RS232/USB interface (Selection ),Automatically record water quality data for a whole year, and the whole machine is in line with  GLP

 

■ All pipelines have been obtained NSF Certified, new quick plug connector, more convenient filter column replacement and maintenance

 

■ Original super long life composite KDF Pre-filter columns can be reduced by 1 year without replacement and operating costs

 

■ American Dow DOW Produced RO Diaphragm, realized RO The combination of long life of the membrane and high-quality water quality

 

■ Original imported nuclear resin, 4-column fully sagging ultrapure column design, always guaranteeing top-level water quality

 

■ Double wavelength (185nm&254nm)UV UV lamp assembly (Imported light tubes ),Effectively sterilize and reduce TOC, Enhanced system scope

 

■ MWCO5000D UF Ultrafiltration components (Original imported ),Effectively remove endotoxins (It's a heat source ),Can be used in precision cell culture and IVF

 

■ (0.45+0.1)µm import PES Polyethersulfone composite filter terminal sterilization filter to ensure absolute sterility of water quality


Technical parameters:

Product model

Master-R

Master-R UF

Master-R UV

Master-R UVF

System Process

PF+KDF+AC+RO+RO+(UV)+AC+DI+(UF)+TF

Application areas

PLC,IC,ICP-MS,GF-AA、 Precision instrument analysis, analytical reagents and pharmaceutical configuration, dilution, physics, electrochemistry and interface research, molecular biology and life sciences, animal and plant cell culture

Pure water

index

RO Reverse osmosis water index

Level 1 RO water (TDS):Conductivity ≈source water Conductivity ×5%,Level 2 RO water (TDS):1-5μs/cm(Conductivity ≤source water Conductivity ×2%)

DI High purity water index

Master-R-RD series:
Resistivity: 16-18.2 MΩ.cm, Heavy metal ions <0.1ppb, microorganism /bacteria <1>0.22μm)<1/ml

UP Ultrapure water index

Master-R series:
Resistivity: 18.2 MΩ.cm@25℃,Heavy metal ions <0.1ppb, microorganism /bacteria <1>0.22μm)<1/ml
Total organic carbon (TOC)<10ppb,(UV/UVF type: TOC<3ppb,UF/UVF Type: Heat source <0.001EU/ml)

technology

Specification

Yield

15-20Lift /Hour

Level 2 RO Instant water output

 2.0Lift /minute

Water outlet (Touch the keys )

3indivual:
Level 1 and 2 RO reverse osmosis water, UP Ultrapure water

External dimensions /weight

long ×Width ×High: 50 ×36×54cm/About 30 Kg

power supply /power

 220V、50Hz/120W

Control system

Operation mode display

 The power supply is turned on, the program is running, the water inlet is flushed, the water is produced, the water is full, the water is withdrawn regularly, the water inlet and outlet exceeds the standard, the life of the consumables and the replacement reminder

Safety performance

 Automatic memory restart, no water, low water pressure, full sound and light alarm, source water, RO Alarms for excessive water and ultrapure water, alarms for terminal consumables, system password, water withdrawal is prohibited during alarm, etc.

System monitoring

source water ,one /Level 2 RO water ,Level 2 RO water /Highly pure water /Super pure water Three ways water Quality monitoring, water Temperature monitoring, consumable usage time and remaining life monitoring, etc.

Water inlet requirements

City water: TDS<200 cm2="" tds="">200ppm When using external softener, it is recommended to choose )

Standard configuration

Host (Contains 1 set of purification columns )+Combined water tank (20Lift PE Water tank ×1+15Pressure-raising bucket ×1)+Accessories
Remark

  Water inlet TDS=200ppm,25˚C,50psi and 15% recovery ratio were measured.

  GPD=gallon /Day, 1 gallon =3.78Lift.  

  The quality of the inlet water will affect the quality of the pure water and the life of the filter column.  

  PF: Pre-filtering KDF: Copper-zinc alloy AC: Activated Carbon RO: reverse osmosis DI: Ion exchange UV: UV lamp sterilization and dissipation UF: Ultrafiltration TF: Terminal microfiltration