Three letters SX823 Portable pH/Conductivity meter
Price:¥3580

Product Description
1. Use 4.3 inches TFT Touch screen, new UI Design, navigational operation experience, support sliding operation;
2. Intelligent operating system, with functions such as method management, electrode management, calibration management, data management and user management;
3. Support electrode management, up to 5 can be managed pH Electrode, 5 ion electrodes, 5 conductive electrodes, 5 dissolved oxygen electrodes; Each electrode can save 20 sets of correction records ; Supports calibration editing function, convenient calibration ;
Four and 3 reading modes: Smart-Read:“ Fast, medium and strict, customize" multiple balance conditions to choose from;
Timed-Read: Two timing reading modes: timing termination measurement and timing automatic interval measurement.;
Cont-Read: Clearly grasp the continuous change process of the sample;
5. Support manual /Automatic temperature compensation;
six, pH/pX Measurement module functions:
Ø Supports measurement of potential value, pH value, pX value, ORP Value, ion concentration and temperature;
Ø Supports electrode correction function, automatic identification GB、DIN、NIST、MERK、JIS Many more pH Buffer solution, up to 8 points of correction; Supports standard liquid group management function, allowing users to create their own standard liquid ;
Ø Allows measurement of a variety of conventional ions, and the instrument randomly provides a variety of commonly used ion modes such as: H+、Ag+、Na+、K+、NH4+、Cl-、F-、NO3-、BF4-、CN-、Cu2+、Pb2+、Ca2+,Convenient for users;
Ø μg/L、mg/L、g/L、mol/L、mmol/L Quick switching of multiple ion concentration units;
Ø It has a variety of ion concentration measurement modes, supports direct-read concentration measurement mode, standard addition measurement mode, sample addition measurement mode, GRAN Measurement mode.
7. Conductance measurement module functions:
Ø Supports measurement of conductivity, resistivity, and total solid dissolved substances ( TDS)、 Salinity, ash and temperature values;
Ø Supports automatic identification of conductivity standard solutions, default 4 types JJG Standard standard liquid, supports multi-point correction of up to 5 points;
Ø Supports multiple conductivity compensation methods including pure water compensation;
Ø Supports multiple salinity compensation methods including seawater salinity compensation;
Ø Within the full range of measurement, it has functions such as automatic temperature compensation, automatic calibration, automatic range, automatic frequency switching, etc.;
8. Dissolved oxygen measurement module:
Ø Supports measurement of dissolved oxygen concentration, dissolved oxygen saturation, dissolved oxygen current and temperature values;
Ø Supports zero-oxygen and full-scale correction for dissolved oxygen; Supports manual and automatic compensation of dissolved oxygen atmospheric pressure ;
Ø Supports multiple atmospheric pressure units kPa、mbar、Torr、Atm。
9. Support storage of 1,000 sets of measurement results, comply with GLP specification; Supports multiple reference methods, and can check storage data according to storage number and storage time, and the reference results are displayed in a curved manner. ;
10. Support two operating languages in Chinese and English; support USB connect PC; Support firmware upgrade function.
Technical parameters:
| model | DZB-718L | ||||
| Technical parameters | pH/pX Module | Conductance module | Dissolved oxygen module | ||
| Instrument Level | 0.001class | 0.5class | ±0.30mg/L | ||
| Measurement parameters | pH/pX、 Potential, | Conductivity, resistivity, | Dissolved oxygen, dissolved oxygen | ||
| Ion concentration, temperature | TDS、 Salinity value, temperature | Saturation, temperature | |||
| Measurement range | pH/ pX | (-2.000~20.000)pH | ● | — | — |
| (0.000~14.000)pX | |||||
| Potential | (-1999.99~1999.99)mV | ● | — | ||
| Ion concentration | (0~19990),unit mol/L、 | ● | — | — | |
| mmol/L、g/L、mg/L、μg/L | |||||
| Conductivity | 0.000μS/cm~3000mS/cm | — | ● | — | |
| Resistivity | 5.00Ω.cm~100.0MΩ.cm | — | ● | — | |
| TDS | 0.000 mg/L~300g/L | — | ● | — | |
| salinity | (0.00~8.00)% | — | ● | — | |
| Dissolved oxygen | (0.00~99.99)mg/L | — | — | ● | |
| Dissolved oxygen saturation | (0.0~600.0)% | — | — | ● | |
| temperature | (-5.0~130.0)℃ | ● | — | — | |
| Resolution | pH/pX | 0.001 pH/pX;0.01 pH/pX | ● | — | — |
| Potential | 0.01 mV,0.1mV | ● | — | — | |
| Ion concentration | Five valid numbers | ● | — | — | |
| (Scientific notation method) | |||||
| Conductivity | 0.001μS/cm | — | ● | — | |
| Resistivity | 0.001Ω·cm | — | ● | — | |
| TDS | 0.001mg/L | — | ● | — | |
| salinity | 0.01% | — | ● | — | |
| Dissolved oxygen | 0.01mg/L | — | — | ● | |
| Dissolved oxygen saturation | 0.10% | — | — | ● | |
| temperature | 0.1℃ | ● | — | — | |
| Basic error | pH/ pX | ±0.002pH/pX | ● | — | — |
| Potential | ±0.1mV or ±0.03% | ● | — | — | |
| Ion concentration | ±0.3% | ● | — | — | |
| Conductivity | ±0.5%(FS) | — | ● | — | |
| Resistivity | ±0.5%(FS) | — | ● | — | |
| TDS | ±0.5%(FS) | — | ● | — | |
| salinity | ±0.1% | — | ● | — | |
| Dissolved oxygen | ±0.10mg/L | — | — | ● | |
| Dissolved oxygen saturation | ±2.0% | — | — | ● | |
| temperature | ±0.1℃ | ● | ● | ● | |
| power supply | Rechargeable lithium battery (DC 3.8V) | ||||
| size( mm), weight( kg) | 201 mm×96 mm×55 | ||||
Price:¥3580
Price:¥4920
Price:¥6600
Price:¥4520
Price:¥1600
Subscription number