Product/Brand

Mini Vortexers
Shanghai Yuejin Desktop Constant Temperature Oscillator HTHZ-92A
Price:¥5880

WeChat

Brand:HENGZI
Model:HTHZ-92A
Inventory Status:Spot promotion/please call for consultation
Contact:
Tel:+86 010-51660436
Email:dnyc_sales@163.com
Details Documentation Related

Desktop constant temperature oscillator

Scope of application
The oscillator ( Commonly known as rocking bed ) It is one of the main equipment for microbial culture. Choose special motors. Temperature control and speed measurement are all imported. Widely used in biological, medical, pharmaceutical, food, environmental protection and agricultural scientific research.

Structural features
>The cover is made of a material with better transparency and can directly observe the culture condition.
>It adopts a speed regulation device with innumerable speed variable speed and rotary oscillation.
>The studio is equipped with a fan to form forced convection to make the average studio temperature better.
>82A Type, 82 N Type: Double LED The numbers show the temperature and speed respectively.
>92 Type: The temperature control is controlled by a temperature controller. LED Digital display


Technical parameters:

Index Model

THZ-82A

THZ-92A

THZ-92B

THZ-92C

THZ-82N

Temperature control range (℃ )

Room temperature RT+3~50

Temperature fluctuation (℃)

±0.5

Temperature uniformity (℃)

±1

Speed / point (min)

50~250

50~300

50~250

Rated power (W)

400

450

300

Operation form

Rotate

Rotate

Rotate + Repeat

Repeat

Rotate

amplitude (mm)

30

30

Timing range

 

0~120min

0~999

External dimensions (cm)

73x42x48

71x46x41

70x48x46

Interior room size (cm)

46x40x28

46x36x25

54x40x30

Packing box size (cm)

87x56x65

80x55x56

77x57x59

net weight / Gross weight (kg)

47/60

43/58

46/60

two. Temperature controller: 

Featured Description 

(1) Temperature sensor temperature: DIN A class Φ5mm SUS Made of stainless steel PT 100×1 branch .

(2) Temperature control method   P.I.D Automatic calculation + Fuzzy control.

(3) Temperature conversion: linear compensation correction for microcomputer.

(4) Display interface  LED Digital tube display, key input method.

(5) Humanized operation

     a. Automatically control the refrigeration compressor and temperature electric heating output power adjustment, P.I.D Calculus control…etc.

     b. Safety self-test The safety self-test of the main system components is the main system components. When an abnormality occurs, the status is indicated by the controller and the operation is stopped.

     c. Independent control controller will heat up /All functions such as cooling are completely independently controlled.

Main functions

(1) Temperature display accuracy 0.1 ℃ 。

(2) Temperature control accuracy   ± 0.1℃ 。

(8) Deviation value correction temperature deviation value compensation and correction function.

(9) I/O Self-test Safety self-test function, automatic power outage protection and fault indication when abnormality occurs.

(11) Automatic calculation microcomputer automatic calculation P.I.D. , Combined with solid state relay power control, temperature control is more accurate (proportion, integral, differential +Solid-state relay control method )。

(12) The upper and lower limits of temperature protection can be set.

(13) The protection device controller monitors the safety protection system and preventive fault self-test control.

three. Structure and material:

(1) Inner box material    SUS-304 Stainless steel mirror panel.

(2) External material  SPCC Cold-rolled steel plate electrostatic powder paint treatment.

(3) Insulation material: high-density polystyrene foam and ultrafine glass fiber wool.

(4) Box lid

     a. Box lid  

82Model: Large transparent acrylic observation window.

92Type: Tempered glass observation window.

     c. Opening direction

Top lift design, opening from bottom to top; N Type is supported by gas spring /closure.

(5) Supports large-size rubber feet.

Four. Temperature electric heating and circulation:

(1) Air supply method: High impedance motor axial flow fan. The air supply method is a horizontal air outlet arc cycle design.

(2) Heating system Microcomputer intelligent automatic control electric heating power balance temperature regulation +High-performance stainless steel tube heater.

five. Safety protection device:

(1) Circuit Breaker Small switch circuit breaker.

(2) Controller internal protection

     a. Temperature and humidity sensors, open or short circuit (Overrange )。

     b. High temperature protection setting for the overtemperature protection setting temperature.

(3) External fault detection protection

     a. Electric thermal protection overload protector (Temperature set 1 )。

(4) Failure abnormality alarm When a fault abnormality occurs, the power off protection will be automatically issued and an alarm sound will be issued.

six. appendix:

(1) . The product instruction manual contains simple troubleshooting instructions and product maintenance instructions.

(2) . fuse

(3) . Certificate of conformity

seven. Power supply: 1 Ø 220V 50Hz

eight. Ambient environment: Ambient temperature range that can be used: 5 ~35 ℃ ,Ambient temperature range for optimal performance: 15 ~30 ℃。

  • Tel:+86 010-51660436
  • Zip code:10000
  • Email:dnyc_sales@163.com
  • Address:4th Floor, East Side, Building A6, Area A, No. 80 Xingshikou Road, Haidian District, Beijing