Psychological Industry HD-9706 Computer nucleic acid protein detector
Price:¥20000

Product Description
HD-7 High sensitivity ultraviolet detector (computer data acquisition) is an ultraviolet device in liquid chromatography. The instrument is equipped with chromatography columns, constant flow pumps, some Shanghai West, etc.
That is, a complete liquid chromatography separation and analysis system is composed of modern biological research, drug determination, agricultural scientific research, chemical engineering
Food and medical units make qualitative and semi-quantitative analysis of samples with ultraviolet absorption.
The main components of this instrument are imported, photomultiplier tube IP28 type, stable performance, high sensitivity, etc.
Product Features
1、This instrument is equipped with output 10 mV In addition to the recorder signal, it is also equipped with an output port suitable for the computer integrator, which is very convenient to form a chromatographic workstation system.
2、The digital display of the instrument is designed to be fixed light absorption, A Display computer-friendly and variable-range light absorption ATwo optional modes for display recorder
This can facilitate standardizing readings, and at the same time, high-sensitivity readings of variable ranges can be performed according to scientific research needs, which can facilitate detection of low-concentration samples.
3、This instrument adopts a new type of import IP28 The photomultiplier tube and improved circuit structure make the instrument work more stable and reliable.
Functional Features
1)Comes with 10 mv Output
2)Select the range with button type
3)The indicator light is on after selecting the range.
4)The front-dial dial is used to adjust the wavelength, so the filters and the filters are not easily damaged.
5)use LED Digital display data.
6)Internal wide voltage design, suitable for complex power supply environments.
Application areas
1)Biological Research
2)Drug Assay
3)Agricultural Research
4)Chemical experiments
5)Food experiments
6)Medical experiments
Technical parameters
model | HD-7 High sensitivity ultraviolet detector |
Detect wavelength | 214、254、280、380nm |
Range measurement range | 0-100%T、0-2A、0-1A、0-0.5A、0-0.2A、0-0.1A、0-0.05A |
Adjust the range method | Button style |
Adjust the range display method | LED lamp |
Noise accuracy matching | Range is 0.05 ATime: Noise ≦0.002A。 |
Integrator output: | 0.1A/mV |
Output recorder signal | (1-10)mV |
Minimum detection | 50ug/ml |
Stabilization time | <20min |
Baseline drift | ≤±1.0×10ˉ³Au/h |
Change the light source method | Front hand adjustment |
Optical range | 10nm( Imported ultraviolet light source) |
Pipeline marking | Chinese labels for liquid inlet and outlet |
Software Configuration | Chromatography software can be connected to the computer to draw chromatography |
Communication interface | COM or USB Interface (used with the collector) |
Working power supply | AC110v-220V±10%;50Hz |
Vibration resistance | Temperature 0 -35℃;Relative humidity 85% |