Chromatography Chamber
Shanghai Jiapeng Automatic Liquid Chromatography Separation Chromaterial 2001- B-III
Price:¥40460

WeChat

Brand:JIAPENG
Model:2001-B-III
Inventory Status:Spot promotion/please call for consultation
Contact:
Tel:+86 010-51660436
Email:dnyc_sales@163.com
Details Documentation Related

HD-97-1 UV detector wavelengths 220, 254, 280, 340 nm;BSZ-100 Timing range: 1 minute-24 hours, collection capacity: 12 ml×100;HL-2 Constant flow pump flow: 2 ×(1-600)ml/h, Pressure: 3 kg/cm 。

  Automatic low pressure liquid chromatography separation chromatography 2001- B-I Five-piece set HD-97-1 UV detector, BSZ-100 Partial collector, HL-2 Flow pump, XWT-1044S Recorder, chromatography column: 1.0 cm×50cm,1.0cm×70cm,1.0cm×90cm, One each.   HD-97-1 UV detector wavelengths 220, 254, 280, 340 nm;BSZ-100 Timing range: 1 minute-24 hours, collection capacity: 12 ml×100;HL-2 Constant flow pump flow: 2 ×(1-600)ml/h, Pressure: 3 kg/cm2 ;XWT-1044S Recorder 10 mv,3-60cm/m/h Eight steps of paper-moving speed.  

Automatic low pressure

Liquid chromatography

Separation chromatometer

2001-B-I

Five-piece set

HD-97-1 UV detector, BSZ-100 Partial collector, HL-2 Constant current
Pump, XWT-1044S, Desktop recorder instrument car, chromatographic column: 1.0 cm
×50cm,1.0cm×70cm、1.0cm×90cm One each.

set

HD-97-1 UV detector wavelengths 220, 254, 280, 340 nm;
BSZ-100 Timing range: 1 minute-24 hours, collection capacity: 12 ml×100;
2 HL-2 Constant flow pump flow: 2 ×(1-600)ml/h, Pressure: 3 kg/cm ;
XWT-1044S Recorder 10 mv,3-60cm/m/h, Eight steps of paper removal,
Ordinary chromatography columns, chromatography column racks, clips, silica gel tubes.

2001-B-II

Six-piece set

HD-2000,BSZ-100, BT-100,XWT-1044S, Instrument car,
Cylinder: 1.0 cm×50cm、1.0cm×70cm、1.0cm×90cm
One each.

set

HD-2000 UV detector wavelengths 220, 254, 280, 340 nm;
BSZ-100 Timing range: 1 minute-24 hours, collection capacity: 12 ml×100;
2 BT-100 Constant flow pump flow: 2 ×(1-600)ml/h, Pressure: 3 kg/cm ;
XWT-1044S Recorder 10 mv,3-60cm/m/h, Eight steps of paper-moving speed.
Ordinary chromatography columns, chromatography column racks, clips, silica gel tubes.

Automatic low pressure

Liquid chromatography

Separation chromatometer

2001-B-III

Six-piece set

HD-2000,BSZ-160, HD-A,HL-2B, Instrument car,
Chromatography column: 1.6 cm×50cm、1.6cm×70cm、1.6cm×90cm
One each.

set

HD-2000 UV detector wavelengths 220, 254, 280, 340 nm;
BSZ-160 Timing range: 1 minute-24 hours, collection capacity: 5 ml×160;
2 HL-2B Constant flow pump flow: 2 ×(1-600)ml/h, Pressure: 3 kg/cm ;
HD-A The collector can realize computer drawing, saving data, analyzing and computing.
Ordinary chromatography columns, chromatography column racks, clips, silica gel tubes.

2001The series of automatic low-pressure liquid chromatography separation analyzers can be newly configured according to separation needs, including nucleic acid protein detectors, automatic partial collectors, cross-flow pumps, chromatography columns, instrument cars, etc. That is, a complete set of liquid chromatography analysis devices are formed, and the instrument car can be easily moved and saved, and it is easy to operate and use, etc.

 