Shanghai Hengping Gas Chromatography GC112A-2
Price:¥30000

The instrument has better performance
GC1120 The gas chromatograph is GC112A Based on the new gas chromatography launched, it not only adheres to GC112A Many excellent qualities in turn make ordinary functions more advanced, more precise and higher technical specifications.
Display the screen clearly at a glance
A large-screen monitor realizes Chinese menu-style dialogue, making the display clearer and easier to operate. It can display the chromatographic spectrum, the progression curve, the base current level, and display the temperature set values and actual values of column boxes, samplers, detectors, etc. in one screen, which can provide more colorful instrument information.
Digital carrier gas flow monitoring system
GC1120 The gas circuit system can be equipped with the latest digital flow monitoring unit, which displays the carrier gas flow and capillary shunt flow value through the screen, and can display up to four sets of flows, and the flow parameters can be automatically stored to facilitate the recording and call of analysis conditions. Convenient flow regulation and flow ratio calculation without the use of a soap film flowmeter
Rich sample injectors /Detector unit combination
A better expansion configuration can meet various needs. Select more injectors based on the diversity and complexity of the analytical samples /Detector series.
GC1120 Can be diverted from the filling column injection unit and capillary /The split-free injection unit realizes the configuration of 4 kinds of injectors, and up to 3 injectors can be loaded at the same time.
GC1120 Up to 6 high-performance detector options are available, i.e. FID、TCD、ECD、FPD、NPD and PID, Up to 3 detectors can be installed simultaneously. You can also use the detector addition method to easily purchase and install other detectors after the instrument is purchased.
Brand new built-in acquisition system
GC1120 The advanced built-in acquisition device can collect instrument control status and chromatographic output signals, enabling the use of a communication line to connect to external computers for real-time instrument control and data processing.
Real-time instrument control includes various temperature control, detector selection and setting, program temperature increase control, process increase curve tracking, flow value display (optional).
Data processing includes high-speed acquisition of dual-channel (scalable to multi-channel) chromatographic data, automatic or manual setting of integral parameters, up to 5 quantitative methods, baseline deduction, report preparation and other functions.
Specification | Main configuration |
GC1120-1 | Capillary injection system (including diaphragm purge, back pressure valve diverter) +Tail blowing adjustment +FID |
GC1120-2 | Double-filled column injection system +TCD |
GC1120-3 | pair Filled column injection system +pair FID |
GC1120-4 | Single-filled column injection system +Independent capillary injection system (including diaphragm purge, backpressure valve diverter) +Tail blowing adjustment +pair FID |
GC1120-5 | pair Filled column injection system +Independent capillary injection system (including diaphragm purge, backpressure valve diverter) +Tail blowing adjustment +pair FID |
GC1120-6 | pair Independent capillary sampler system (including carrier gas control, diaphragm purge, back pressure valve diverter, independent temperature control) +pair Tail blowing adjustment +pair FID+Filling column injection accessories (modified on capillary injector) |
Note: The above are commonly used configurations. Users can make any configuration combination according to special needs. Please explain it when ordering.
Main technical indicators
Temperature control
Temperature control range: 7 at room temperature ℃~400℃ (Increment 1 ℃)
Temperature control objects: column box, detector, thermal conductivity pool, sampler, auxiliary
Number of upgrades: eighth order
Range rate: 0.1 ℃~40℃/min (Increment 0.1 ℃)
Constant temperature time: 0 ~655min (Increment 1 min)
Flame photometric detector ( FPD)
Detection limit: ≤1×10-11g/s(P)
Sample: Methyl parathion
≤1×10-10g/s(S)
Sample: Methyl parathion
Hydrogen flame ionization detector (FID)
Sensitivity: M≤8×10-12g/s sample: C16
Best test results: M≤3×10-12g/s sample: C16
Nitrogen and phosphorus detector ( NPD)
Detection limit: ≤5×10-12g/s(N)
Sample: Azobenzene
≤5×10-13g/s(P)
Sample: Malathion
Thermal conductivity detector (TCD)
Sensitivity: ≥5000mV·mL/mg sample: C16
Maximum sensitivity: ≥10000mV·mL/mg( Optional electronic amplifier board)
Electronic capture detector (ECD))
Detection limit: ≤1×10-13g/ml sample: γ-666
Maximum service temperature: 350 ℃
Photoionization detector ( PID)
Detection limit: ≤1ppb
Sample: benzene
Main accessories | Functional introduction |
GC1120-TCD Thermal conductivity detector | High-quality rhenium tungsten wire, constant current source control, double-filled column balance mode, optional amplifier. |
GC1120-FPD Flame photometric detector | Dual flame structure, optical fiber optical signal transmission, has a high response value to trace amounts of phosphorus and sulfur organic matter. |
GC1120-ECD Electronic capture detector | use NI63 Radioactive sources have extremely high sensitivity to substances with strong electronegativity, such as halogen compounds. |
GC1120-NPD Nitrogen and phosphorus detector | Imported high-stability beads have a high response value to nitrogen-containing and phosphorus-containing organic matter. |
GC1120-PID Photoion detector | Non-destructive detection, using photons to achieve sample ionization, no radioactive source, theoretically detectable ionization potential below 10.6 eV All gas (vapor) compounds |
Digital traffic monitoring module | Each module can collect the air flow value, and connect it to the motherboard to realize real-time flow digital display. |
Capillary shunt /Split-free sample injection system | Capillary shunt /Split-free sampler can control the temperature separately, independent gas circuit (including carrier gas control, diaphragm purge, back pressure valve split), tail blowing adjustment, imported cleaning solenoid valve, and control the split by preparing time programs. /Injection without diversion. |
Liquid automatic sampler | Achieve automatic injection of chromatographic liquid samples, up to 110 samples in the sample disk. |
Headspace sampler | The sample is sealed in a sample vial and heated for a certain period of time to analyze the top air in the gas phase. Suitable for volatile components analysis of solid and liquid. |
Thermal analyzer | Sample air is introduced into the adsorption tube, and the volatile components are retained in the adsorption tube. The adsorption tube was heated to desorb the collected vapor (volatile organic compounds), and the sample to be tested entered the chromatograph with the inert carrier gas for analysis. |
Simulation software | Simulate and find chromatographic conditions for chromatographic simulation teaching, training and knowledge base calls. |