Product/Brand

CO₂ Incubator
Shanghai Yiheng Carbon Dioxide Incubator BPN-150CH(UV) Air sleeve type
Price:¥27900

WeChat

Brand:yiheng
Model:BPN-150CH(UV)
Inventory Status:Spot promotion/please call for consultation
Contact:
Tel:+86 010-51660436
Email:dnyc_sales@163.com
Details Documentation Related

A new generation BPN The series carbon dioxide incubator is original HH·CP The upgraded product of the series of carbon dioxide incubators. The company has been developing and manufacturing experience in this field for nearly 20 years. It is guided by the needs of users, constantly researching new technologies and applying them to products, using infrared CO2 Sensors control accurate temperature and are not affected by temperature and humidity.

◆Humanized design 

● Stackable (Second floor ),Easy to make full use of laboratory space, microcomputer controller, precise and reliable control. It uses stainless steel inner liner and shelf, and the four corner semi-circular arc transitions. The shelf bracket can be loaded and unloaded freely, making it easy to clean the studio.

Infrared sensor

infrared( IR)The sensor has the characteristics of monitoring the speed of carbon dioxide gas and is not affected by external temperature and humidity fluctuations. Even if multiple people use it, they need to open and close the door frequently. CO2 Stable and uniform concentration. Thermal conduction sensor is easily affected by temperature and humidity, and has a long response time and large detection errors. If used for a long time, it requires frequent calibration and other defects.

◆Microbial high-efficiency filter 

● CO 2 The air inlet is equipped with high-efficiency microbial filter for diameters greater than or equal to 0.3 μ m The filtration efficiency of particles is as high as 99.99%, effective filtration CO2 Bacteria and dust particles in the gas.

◆Automatic control of circulating fan speed 

● The speed of the circulating fan can be automatically controlled. When the temperature in the box is in a constant temperature state, the speed will decrease, and the circulating wind speed will be adjusted to a wind speed suitable for cell growth, avoiding the volatility of the sample due to excessive air volume during the test.

◆Door temperature heating system 

● The incubator door can heat the inner glass door, which can effectively prevent the glass door from producing condensation water and prevent the possibility of microbial contamination due to the condensation water of the glass door.

◆Safety features 

● Independent temperature limit alarm system (optional) to ensure safe operation of the experiment without accidents.

● Low temperature, high temperature, overtemperature alarm and long door opening time.

◆UV sterilization system 

● The ultraviolet sterilization lamp is located on the back of the top of the box, and can regularly disinfect the inside of the box, which can effectively kill the floating bacteria of circulating air and humidified steam in the box, thereby effectively preventing contamination during cell culture.

Technical parameters 

model

BPN-50CH(UV)

BPN-80CH(UV)

BPN-150CH(UV)

BPN-190CH(UV)

BPN-240CH(UV)

BPN-30CW(UV)

BPN-80CW(UV)

BPN-150CW(UV)

Power supply voltage

AC220V 50HZ

Input power

450W/500W

750W

950W

250W/680W

950W

Heating method

Air sleeve type

Water cover type

Temperature control range

RT+5~50℃

Working ambient temperature

+5~30℃

Temperature fluctuation

±0.2℃

±0.1℃

CO2 Control range

0-20%

CO2 Control accuracy

±0.1% (Infrared sensor )

CO2 Recovery time

(Recover to 5% after opening the door in 30 seconds )≤3minute

Temperature recovery

(Recover to 37 in 30 seconds after opening the door ℃)≤8minute

Relative humidity

Natural evaporation ≥90%

Volume

50L/80L

150L/190L

240L

26L/80L

150L

Inner liner size ( mm)W×D×H

400×350×350

400×450×500

480×530×610

520×530×690

600×630×670

290×290×310

400×400×500

500×500×650

Dimensions ( mm)W×D×H

580×450×540

590×657×870

670×710×950

708×710×1030

788×837×940

440×410×544

550×520×764

650×615×914

Carriage bracket (standard)

2piece

2piece

3piece

2piece

3piece

Disinfection method

UV UV disinfection

Note: All technical data are for the device at 25 ℃Detection in the environment.

Optional parts: (Add to 7 days for optional parts delivery)

1、RS485 Interface and communication software

2、Special carbon dioxide pressure reducing valve

3、Humidity display system

4、Independent temperature limit controller

5、Embedded printer

Note: RS485/232、Choose one of two printers