Product/Brand

Gravity-Convection Incubator
Shanghai Yiheng Microbial Incubation Box DHP-9011
Price:¥3040

WeChat

Brand:yiheng
Model:DHP-9011
Inventory Status:Spot promotion/please call for consultation
Contact:
Tel:+86 010-51660436
Email:dnyc_sales@163.com
Details Documentation Related

Technical parameters

model

DHP-9011

DHP-9031

Power supply voltage

AC220V    50HZ

Temperature control range

RT+5~65℃

Temperature resolution /Volatility

0.1℃/±0.5℃

Working ambient temperature

+5~35℃

Input power

85W

125W

Volume

10L

35L

Inner liner size (mm)W×D×H

250×200×200

320×300×320

External dimensions (mm)W×D×H

460×300×330

530×400×450

Carriage bracket (standard)

2piece

2piece

Features

l  Mirrored stainless steel inner liner is convenient for studio cleaning.

l  Natural convection circulation is adopted to avoid volatility of samples during the test.

l  The heating film heating method is the heating temperature in the box, and the ventilation volume can be adjusted through the top ventilation skateboard.

l  There is an observation window on the box door to facilitate the observation of the experimental process in the box.

l  Vague PID Controller, precise temperature control fluctuations are small, with timing function, the maximum time setting value is 99 hours and 99 minutes.    

l  Independent temperature limit alarm system, the temperature exceeds the limit will be automatically interrupted, ensuring safe operation of the experiment without accidents. (Selection )

◆LCD multi-stage programmable controller (optional)

l  Microcomputer program controller, time and heating rate, conduct heating and drying tests at extremely fast speed.

l  15 segments can be preset and 30 steps can be programmed, and each segment can be set for 1 time ~9999 minutes.

l  Multi-stage programmable control can simplify complex experimental processes and truly realize automatic control and operation.

◆Safety features

l  Independent temperature limit alarm system, and sound and light alarm reminds the operator to ensure safe operation without accidents. (Optional)

l  High or low temperature and overtemperature alarm.

◆UV sterilization system (optional)

l  The inside of the box can be disinfected regularly, which can effectively kill the floating bacteria in the circulating air in the box, thereby effectively preventing contamination during cell culture.