Product/Brand

Vertical Autoclave
Shanghai Boxun fully automatic autoclave BXM-150M
Price:Discuss personally

WeChat

Brand:Boxun
Model:BXM-150M
Inventory Status:Spot promotion/please call for consultation
Contact:
Tel:+86 010-51660436
Email:dnyc_sales@163.com
Details Documentation Related

Scope of application
The sterilizer series products are quick and reliable disinfection and sterilization equipment that uses pressure saturated steam to perform rapid and reliable disinfection and sterilization of products. They are suitable for pharmaceutical, scientific research, agriculture and other units. They can disinfect and sterilize dressings, glassware, solution culture medium, etc.

Suitable for sterilization: autoclave steam sterilization of conventional sterilization materials such as culture medium, instruments, glassware and containers; Relatively sealed container sterilization (cilin bottles, blue cap bottles, etc.), large volumes of dense sterilization substances (such as large instrument packs, large bottle culture medium, and dense fabric packs). These sterilization substances have a pre-vacuum function to ensure the thoroughness of cold air emissions, improve steam penetration, and ensure sterilization effect. ; For samples that need to be dried after sterilization, such as: vessels, instruments, fabrics, clothing, etc., this sterilizer has its own pulsating vacuum drying function, which has a good drying effect, avoiding the risk of secondary contamination during the transfer and drying process after sterilization ; Bio-polluting waste sterilization, this sterilization pot has an efficient filtration system when venting cold air, which can effectively isolate biohazards.

Functional Features
The organic combination of metal materials and plastic parts is adopted to effectively isolate the surface temperature during working state while ensuring the durability of the body, ensuring operational safety;
New one-button electric door opening structure with dual protection of mechanical self-locking and electronic interlocking;
PMMA III Operating system, LCD touch screen, touch display integrated, controlled by microcomputer intelligent program, easy to operate and read information;
It has 16 custom modes to set and save, making it convenient for customers to preset different sterilization programs according to different sterilization substances, and then call them directly every time they are used.;
With data storage function and available U Data export and backup disks in unchangeable file format to ensure traceability of the sterilization process;
Steam generation is completely isolated from the cavity, and there is no heating element in the sterilization cavity, which improves the utilization rate and heating efficiency of the cavity, making it easy to clean and maintain;
It has a pre-vacuum function to ensure thorough cold air emissions and improve saturated steam penetration;
It has a pulsating vacuum drying function to ensure that special samples can be directly dried after sterilization, and there is no clear water in the cavity, so there is no need for high-pressure drainage when drying;
Both the sterilization cavity and the sterilization net basket are SUS304 Made of stainless steel, resistant to acid, alkali and corrosion;
The sterilized cavity adopts mirror polishing process to facilitate cavity cleaning;
Standard condenser +Quick fan cooling system to shorten the waiting time for opening the cover;
Built-in high-efficiency filtration system can ensure biological pollution isolation during cold air discharge, and avoid pollution of sterilized samples by external air during negative pressure compensation.;
Dual automatic water replenishment channels, can select water sources and automatically add water when water is short;
Standard sample temperature probe can monitor the temperature of sterilized items in real time to avoid tedious sterilization process verification;
With C.W.S Recycled water can be utilized using a system that can circulate condensate generated during sterilization.;
With W.P.S The wastewater and waste gas purification system can effectively filter the water gas generated during the waste sterilization process and then discharge it.

Optional accessories
Water storage system can be optional when there is no water source;
When there is no floor drain, you can choose a waste liquid collection box;
Optional auxiliary elevator for easy placement and extraction of sterilized items;
Optional printer, the printer can print time, temperature, pressure, F0 Value and process curve.

Technical parameters:

model

BXM-150M

temperature

Sterilization

105~135℃

dry

102℃

melt

40~100℃

Insulation

25~85℃

time

Sterilization

4~999Min

dry

0~999Min

melt

0~999Min

Insulation

0~999Min

reserve

99Hrs60Min

pressure

design

0.25MPa

Work

0.22MPa

Pulsational vacuum

0   Freq,2~99Freq

Drying degree

<1%

Heating power (kW)

10.5

environment

power supply

~380V±38V,50HZ±1HZ

temperature

5~40℃

humidity

20%~80%RH

Specification

External dimensions (mm)

850×910×1180

Cavity size (mm)

Ø500×870

Volume

150L

Net basket

Ø460×180×4indivual


Functional configuration table:

Configuration name

●Configure as standard
  ○For optional configuration

Overpressure self-locking device

Cover inspection system

Ultra-temperature protection function

Water cut protection system

Overpressure protection system

Automatic pressure relief function

Electric switch door

Preheating function

Fault self-test function

Appointment function

Melt insulation function

Automatic water addition

Working status diagram

Quick cooling (air-cooled)

Air filter

Recycled water can be used system: Condensed water generated during sterilization can be circulated

Wastewater and waste gas purification system: It can effectively filter and discharge water gas generated during waste sterilization process

Single-line sample temperature probe

Pallet: Can be placed at the bottom of the net basket

Add water: 2 pieces (pure water and tap water)

Data storage /Export

Auxiliary hoist: convenient placement and extraction of sterilized items

Waste liquid collection box: used to collect waste water and waste gas (if the user has no floor drain)

printer

Siprui special belt, thermal sensitivity (domestic): the printer can print time, temperature, pressure, F0 Value and process curve

Epson ribbon (imported): The printer can print time, temperature, pressure, F0 Value and process curve


  • Tel:+86 010-51660436
  • Zip code:10000
  • Email:dnyc_sales@163.com
  • Address:4th Floor, East Side, Building A6, Area A, No. 80 Xingshikou Road, Haidian District, Beijing