Shanghai Yuejin Hot Air Disinfection Box HGRF-9203
Price:¥8290

Hot air disinfection box (dry heat disinfection box) - LCD display
Scope of application
Using high temperature and dry heat to oxidize microorganisms, denature proteins, and dielectric concentration, causing poisoning
use. It mainly destroys cell protoplasm through oxidation and causes microorganisms to die, so
All microorganisms can be killed within a certain heating time.
Structural features
>Accurate: High-precision microcomputer LCD display temperature controller, accurate and reliable temperature control.
>Rapid: The heat rises quickly, forced convection, the dry and hot air passes directly through the heated object, drying, and disinfection time is significantly shortened.
>Safety: Adopt two sets of overtemperature protection systems. Automatic interruption is automatically achieved after exceeding the limit to ensure the safety of personnel and instruments.
>Convenient: It can be controlled regularly, and the partition can be freely moved and convenient for cleaning in the box, making it convenient for operators.
Technical parameters:
Index Model | GRX-9023A | GRX-9053A | GRX-9073A | GRX-9123A | GRX-9203A |
Power supply voltage | 220V 50Hz | ||||
Temperature control range | RT+10℃ ~250℃ | ||||
Temperature resolution /Volatility | 0.1℃ /±1℃ | ||||
Working ambient temperature | +5℃ ~40℃ | ||||
Input power | 650W | 1000W | 1500W | 1600W | 2450W |
Interior room size (mm) | 300x300x280 | 420x370x350 | 450x450x450 | 550x360x550 | 600x550x645 |
External dimensions (mm) | 580x500x450 | 710x560x530 | 740x640x630 | 830x610x720 | 880x740x820 |
Carriage bracket (standard) | 2 piece | ||||
Timing range | 1~9999min | ||||
two. Temperature controller:
Featured Description
(1) Temperature sensor temperature: DIN A class Φ5mm SUS Made of stainless steel PT 100×1 branch .
(2) Temperature control method P.I.D Automatic calculation + Fuzzy control.
(3) Temperature conversion: linear compensation correction for microcomputer.
(4) Display interface LCD LCD screen display, key input method.
(5) Timing range 1.1 ~9999minute ; 2. No timing continuous operation
(6) Humanized operation
a. Automatically control the temperature and heating output power adjustment, P.I.D Calculus control…etc.
b. Safety self-test The safety self-test of the main system components is to indicate the status through the controller when an abnormality occurs and the heating is stopped.
Main functions
(1) Temperature display accuracy 0.1 ℃ 。
(2) Temperature control accuracy ± 0.1℃ 。
(3) Deviation value correction temperature deviation value compensation and correction function.
(4) I/O Self-test Safety self-test function, automatic power outage protection and fault indication when abnormality occurs.
(5) Automatic calculation Microcomputer automatic calculation P.I.D. , Combined with solid state relay power control, temperature control is more accurate (proportion, integral, differential +Solid-state relay control method )。
(6) Temperature upper and lower limit protection The upper and lower limits of temperature protection can be set.
(7) Protection device: The controller monitors the safety protection system and preventive fault self-test control.
three. Structure and material:
(1) Inner box material SUS Stainless steel mirror panel
(2) External material SPCC Cold-rolled steel plate electrostatic powder paint treatment.
(3) Insulation material: Ultrafine fiberglass cotton.
(4) Box Door
a. Observation window Multi-layer hollow tempered glass window.
b. Opening direction single door design, opening method from left to right.
(5) Shelf stainless steel bar shelf ×2 Block; adjustable height per layer 50 ㎜。
Four. Temperature electric heating and circulation:
(1) Air supply method: High impedance motor centrifugal fan. The air supply method is a horizontal air outlet arc cycle design.
(2) Heating system Microcomputer intelligent automatic control electric heating power balance temperature regulation +Stainless steel tube heater.
five. Safety protection device:
(1) Circuit Breaker Small switch circuit breaker.
(2) Controller internal protection
a. Temperature sensor open or short circuit (Overrange )。
b. High temperature protection setting for the overtemperature protection setting temperature.
(3) Fault abnormality alarm When a fault abnormality occurs, the power and thermal protection will be automatically cut off and an alarm sound will be issued.
Price:¥8290
Price:¥4690
Price:¥5190
Price:¥7590
Price:¥5290
Subscription number